Planning application
The Old Vicarage 13 High Street Bidford-on-Avon Alcester B50 4BQ
Works: Windows or glazing
Permission granted. Work must normally begin within three years of the decision or the permission lapses.
Proposal
Install battery storage system in garage, install back up gateway in utility room, install multi split heating and cooling system in dining room and kitchen, install compressor unit to side elevation, install secondary glazing in drawing room and master bedroom
As published by the council, reference 24/02527/LBC
Application record
- Reference
- 24/02527/LBC
- Type
- Listed Building Consent
- Status
- Listed Building Consent Approved
- Decision
- Granted As published: Listed Building Consent Approved
- Received
- 7 Oct 2024
- Validated
- 7 Nov 2024
- Decided
- 20 Jan 2025
- Ward
- Bidford East
- Parish
- Bidford-on-Avon
- Postcode
- B50 4BQ
Site history
Applications at this address on the Stratford-on-Avon register
This site has had 2 applications since 2024: 1 approved, 1 refused.
-
24/01824/LBP Refused
The Old Vicarage 13 High Street Bidford-on-Avon Alcester B50 4BQ
The proposed works are 1) installation of a battery storage system 2) installation of multi split heating / cooling system to the kitchen and dining room Battery storage It is proposed to install a floor mounted battery storage system within the garage, the batteries will be located on an external wall beneath the existing wall mounted solar inverter. Each battery capacity is 13.5 kwh and each battery measures 1,099 x 609 x 193 mm in size. The batteries will be capable of be charged from the existing solar PV array and from overnight off peak electricity from the grid. It is proposed to install up to 3 batteries. Multi split system installation The multi split heating system comprises 3 main components a) 2 x wall mounted venting units b) 1 x wall mounted compressor unit. It is proposed to wall mount 1 venting unit at high level in each of the dining room extension and the kitchen. The compressor unit is to be mounted low level on the external wall of the dining room. Black pipework will run along the external wall at low level and enter the rear lobby near floor level and run vertically in the corner where it will be discreetly boxed in. There will not be any visible pipework in the kitchen or dining room because the vent units connections are at the rear. The compressor is 804 x 298 x 252 mm in size.
Timeline
Dates from the published record
-
7 Oct 2024
Received by Stratford-on-Avon
-
7 Nov 2024
Validated
Checked as complete and ready for consideration.
-
20 Jan 2025
Decision issued: Listed Building Consent Approved
-
30 Sep 2026
Added to PlanIndex
Documents
Plans, drawings, consultee responses and the officer's report
18 documents on file for this application
A planning file usually holds the application form, drawings and site plans, consultee responses, the officer's report and the decision notice.
Watch members (£5 a month) open the document list from here.
Open the documentsWhat this grant of permission means
Stratford-on-Avon granted permission on 20 January 2025, subject to any conditions on the decision notice. Work must normally begin within three years or the permission lapses. More in our guide to what happens after a planning decision.
About heritage and listed building applications
Listed building consent is needed for works that affect the special interest of a listed building, and carrying out such works without it is a criminal offence. More in our guide to planning application types.
Nearby applications
Within 0.3 miles
-
The Old Vicarage 13 High Street Bidford-on-Avon Alcester B50 4BQ
The proposed works are 1) installation of a battery storage system 2) installation of multi split heating / cooling system to the kitchen and dining room Battery storage It is proposed to install a floor mounted battery storage system within the garage, the batteries will be located on an external wall beneath the existing wall mounted solar inverter. Each battery capacity is 13.5 kwh and each battery measures 1,099 x 609 x 193 mm in size. The batteries will be capable of be charged from the existing solar PV array and from overnight off peak electricity from the grid. It is proposed to install up to 3 batteries. Multi split system installation The multi split heating system comprises 3 main components a) 2 x wall mounted venting units b) 1 x wall mounted compressor unit. It is proposed to wall mount 1 venting unit at high level in each of the dining room extension and the kitchen. The compressor unit is to be mounted low level on the external wall of the dining room. Black pipework will run along the external wall at low level and enter the rear lobby near floor level and run vertically in the corner where it will be discreetly boxed in. There will not be any visible pipework in the kitchen or dining room because the vent units connections are at the rear. The compressor is 804 x 298 x 252 mm in size.
Refused Lawful development Extension 12 docs -
River View 19 High Street Bidford-on-Avon Alcester B50 4BQ
T5-Alder-Fell T6-Alder-Fell
Granted Trees 4 docs -
Bidford Pharmacy 17 High Street Bidford-on-Avon Alcester B50 4BQ
To place solar panels on the rear pitched roof of the building. These will not be visible from the High St. I have detailed drawings from a contractor for the job.
Refused 11 docs -
3 Saxonfields Bidford-on-Avon Alcester B50 4BS
Single storey rear extension
Granted Full applications Extension 10 docsSmall domestic -
47 High Street Bidford-on-Avon Alcester B50 4BQ
4no. replacement windows
Granted Full applications Windows or glazing 23 docs -
47 High Street Bidford-on-Avon Alcester B50 4BQ
Replacement windows
Granted Heritage and listed buildings Windows or glazing 21 docs
Other heritage and listed building applications
In Stratford-on-Avon
-
26/01679/LBC Granted
Swallow House 1 Mill Street Shipston-on-Stour CV36 4AN
Proposed conservatory extension to detached garden room and alterations to open garage/store in rear range of house to create boot room and store
-
25/03122/LBC Granted
Cedars Farm Priors Marston Southam CV47 7RH
Waterproofing Works to the Basement, Repair and Upgrades to sash windows, cleaning and repairs to existing stone, repair and upgrade works to the main roof and chimneys
-
26/01737/LBC Granted
1 Perrymill Cottages Perrymill Lane Sambourne Redditch B96 6PD
Removal of an existing rear door and infilling the opening with brickwork to match the existing; Erection of internal stud wall; Lowering of an existing window cill to create a new door opening; Insertion of two conservation rooflights to the garage roof.
-
26/00022/LBC Granted
Wootton Park Farm Alcester Road Wootton Wawen Henley-in-Arden B95 6HJ
Replacement timber windows to side and rear elevations. Replacement single door to side elevation
-
26/01197/LBC Granted
33-35 High Street And 3 And 4 Wood Street Stratford-upon-Avon CV37 6AU
Internal alterations to separate 33-35 High Street internally from 3 and 4 Wood Street