Planning application
King George V Dock 998 Renfrew Road Glasgow G51 4SD
Still open. Anyone can comment while the consultation period runs, and comments go to the council rather than to us.
Proposal
Installation of underground district heating pipes, ducting and electrical cabling with heat and power offtake; backup energy centre and pumping station; and, all associated works, to serve the Queen Elizabeth University Hospital
As published by the council, reference 26/01053/FUL
Application record
- Reference
- 26/01053/FUL
- Category
- Full applications
- Status
- Pending - Consideration
- Received
- 15 May 2026
- Validated
- 22 May 2026
- Ward
- Govan
- Postcode
- G51 4SD
Timeline
Dates from the published record
-
15 May 2026
Received by Glasgow City
-
22 May 2026
Validated
Checked as complete and ready for consideration.
-
28 Jul 2026
Added to PlanIndex
-
Decision
Awaiting decision
Decision expected by 17 July 2026, 8 weeks from validation under the statutory target for most applications. Extensions of time are common and are agreed case by case.
Glasgow City took a median of 77 days over the applications it decided in the last year.
Who's behind it
Company information only, from the register and Companies House
Savills Limited Agent, registered in London
Active · incorporated 1987 · London
2,120 applications on PlanIndex · across 183 councils · 93% granted
Trade members see everything this firm has filed, how it was decided, and get an email the day it files again.
See their track recordEnergy On Clyde Limited Applicant, registered in Edinburgh
Active · incorporated 2024 · Edinburgh
1 application on PlanIndex
Trade members see everything this firm has filed, how it was decided, and get an email the day it files again.
See their track recordDocuments
Plans, drawings, consultee responses and the officer's report
44 documents on file for this application
- FRA
- GROUND INVESTIGATION
- NOTIFICATION LIST - NEIGHBOURS
- ACOUSTIC REPORT
- AIR QUALITY
- APPENDIX C - ASSESSMENT COMPLIANCE CERTIFICATE
- APPENDIX D - INDEPENDENT CHECK CERTIFICATE
- CDM CONSTRUCTION PHASE PLAN
- COVER LETTER
- DESIGN AND ACCESS STATEMENT
- DOCUMENT TRANSMITTAL
- DRAINAGE LAYOUT
- DRAINAGE IMPACT ASSESSMENT
- EXISTING SITE PLAN
- EXISTING SITE SECTIONS
- FLOOD RISK ASSESSMENT
- GROUND CONDITIONS - PIR PART 1
- GROUND CONDITIONS - PIR PART 2
- GROUND CONDITIONS - PIR PART 3
- GROUND CONDITIONS - PIR PART 4
- GROUND CONDITIONS - PIR PART 5
- GROUND CONDITIONS - PIR PART 6
- A LOCATION PLAN
- PAC REPORT
- PLANNING STATEMENT
- APPLICATION PDF
- BOUNDARY TREATMENT PLAN
- PROPOSED ELEVATIONS
- PROPOSED FIRST FLOOR PLAN
- PROPOSED GROUND FLOOR PLAN
- PROPOSED PIPE BRIDGE
- PROPOSED ROOF PLAN
- PROPOSED SECTIONS
- PROPOSED SITE PLAN INCL SCO WATER ASSETS
- PROPOSED SITE PLAN
- PROPOSED SITE SECTIONS
- PROPOSED SPEN SUB STATION
- PROPOSED WELFARE BUILDING
- TRANSPORT STATEMENT
- TREE PROTECTION PLAN
- TREE PROTECTION PLAN
- TREE PROTECTION PLAN
- VISUAL 1
- VISUAL 2
Watch members (£5 a month) open the document list from here.
Open the documentsWhat happens while it is decided
This application is with Glasgow City for determination, against a statutory target of eight weeks. Over the last year Glasgow City decided full applications in a median of 88 days. More in our guide to how long planning decisions take.
About full applications
A full application seeks permission for a complete, detailed proposal in one go, with siting, design, access and landscaping all fixed at this stage. More in our guide to planning application types.
Nearby applications
Within 500 metres
-
Site Bounded By Hardgate Road/Renfrew Road/ Bogmoor Road Glasgow
Formation of a dedicated public transport (fast bus) and active travel (walking and cycling) link road from Hardgate Road to Bogmoor Road and road widening of Renfrew Road (renewal of Planning Permission in Principle ref.15/02112/DC)
Granted Outline 16 docs -
Site Adjacent To Caravan Park Bogmoor Road Glasgow
Erection of unit (Class 6).
Granted Full applications 27 docs -
345 Renfrew Road Glasgow G51 4SP
Use of vacant land as motorcycle training school (Sui Generis) and siting of two portacabins and one storage container.
Granted Full applications 15 docs -
2 Row Avenue Renfrew Glasgow G51 4SY
Non-Material Variation for the installation of two EV charging spaces and reconfiguring of parking and the relocation of plant associated with planning permission 25/0082/PP
Granted Conditions 8 docs -
2 Row Avenue Renfrew Glasgow G51 4SY
Request to discharge suspensive aspect of Conditions 2 (Site Investigation and Remediation Strategy), 4 (Landscape Plan) and 9 (Pedestrian Routing Plan) of planning permission 25/0082/PP
Granted Conditions 14 docs -
2 Row Avenue Renfrew Glasgow G51 4SY
97% historically approved · decision due ~9 Nov
Non-Material Variation to the approved landscaping scheme of planning permission 25/0082/PP
Awaiting decision
Other full applications
In Glasgow City
-
26/01265/FUL Granted
Premier Inn 187 George Street City Centre Glasgow G1 1YU
Removal and replacement of telecommunications equipment and ancillary development
-
26/01358/FUL Granted
26 Leehill Road Glasgow G21 1XJ
Use of domestic garage as granny flat to side of dwellinghouse.
-
26/01942/FUL Awaiting decision
23 Penicuik Street Glasgow G32 6FR
Erection of single storey extension to rear of dwellinghouse.
-
26/01945/FUL Awaiting decision
7 Ormiston Avenue Glasgow G14 9DT
Erection of single storey extension to rear of dwellinghouse
-
26/01940/FUL Awaiting decision
Queens Park Baptist Church 20 Balvicar Drive Glasgow G42 8QS
Formation of lift and replacement of external porch and stair with steel stair