Skip to content
PlanIndex Get alerts
Menu

Planning application

41 Sandlands Road Walton On The Hill Surrey KT20 7XB

Refused Reigate and Banstead 23/00397/PDE General Permitted Development - Extns

Works: Extension

Refused. Only the applicant can appeal, within the statutory time limit, and a revised scheme can be submitted instead.

Proposal

Ground floor side infill and rear extension. Depth 6m, maximum height 3m, height at eaves 2.6m.

As published by the council, reference 23/00397/PDE

Application record

Reference
23/00397/PDE
Type
General Permitted Development - Extns
Status
Decided (Refused)
Decision
Refused Extension GPD
Received
23 Feb 2023
Validated
23 Feb 2023
Decided
30 Mar 2023
Ward
Lower Kingswood Tadworth And Walton
Decision by
Neighbourhood Development Manager
Postcode
KT20 7XB

Site history

Applications at this address on the Reigate and Banstead register

This site has had 3 applications since 2023: 0 approved, 2 refused.

  • 23/02273/HHOLD Refused

    41 Sandlands Road Walton On The Hill Surrey KT20 7XB

    Ground floor rear and side infill extension

    Decided 18 Dec 2023 Householder
  • 23/01929/PDE Decided

    41 Sandlands Road Walton On The Hill Surrey KT20 7XB

    Single storey rear side infill extension. Max height 3m, height at eaves 2.7m and extending 4.29m beyond the rear wall.

    Decided 24 Oct 2023 Prior approval

Timeline

Dates from the published record

  1. 23 Feb 2023

    Received by Reigate and Banstead

  2. 30 Mar 2023

    Decision issued: Refused Extension GPD

  3. 21 Aug 2026

    Added to PlanIndex

Documents

Plans, drawings, consultee responses and the officer's report

12 documents on file for this application

A planning file usually holds the application form, drawings and site plans, consultee responses, the officer's report and the decision notice.

Trade members open them from here.

Open the documents

What this refusal means

Reigate and Banstead refused this application for the reasons on the decision notice; only the applicant can appeal, and refused schemes often return in revised form. More in our guide to what happens after a planning decision.

About prior approval applications

Prior approval applies where permitted development rights already grant the principle of the work, leaving the council only the specific matters the rules name, commonly within 56 days. More in our guide to planning application types.

Nearby applications

Within 500 metres

  • 41 Sandlands Road Walton On The Hill Surrey KT20 7XB

    23/02273/HHOLD Submitted 6 Nov 2023 0m away

    Ground floor rear and side infill extension

    Refused Householder Extension 14 docs
    Domestic
  • 3 Sandlands Road Walton On The Hill Surrey KT20 7XB

    26/00428/CU Submitted 24 Mar 2026 0m away

    Change of use of first floor from residential (Use Class C3) to dental surgery (Use Class E(e)), including associated internal alterations.

    Granted Full applications 19 docs
  • 41 Sandlands Road Walton On The Hill Surrey KT20 7XB

    23/01929/PDE Submitted 19 Sep 2023 0m away

    Single storey rear side infill extension. Max height 3m, height at eaves 2.7m and extending 4.29m beyond the rear wall.

    Decided Prior approval Extension 11 docs
    Small domestic
  • 12 Pond Farm Close Walton On The Hill Surrey KT20 7RY

    23/01753/LBC Submitted 4 Sep 2023 64m away

    The remedial works are to the main supporting walls of the roof structure due to the form of raised collar roof structure serving. Distress has been suffered to the upper sections of the wall indicating lateral movement of the upper section to this wall. Work carried out in upstairs bedroom.

    Granted Heritage and listed buildings 26 docs
  • 2 Sandlands Road Walton On The Hill Surrey KT20 7XA

    22/02583/TPO Submitted 21 Dec 2022 72m away

    T1 Sycamore - Crown lift all around by 2m - crown thin by 20%. T2 Sycamore - Crown lift by 2m all around - crown thin by 20%. Reduce long lateral limb growing towards neighbour's Conifer, by 3m. G1 Group of Willow - reduce by approx 2m to new form.

    Granted Trees 3 docs
  • Hedge End 36 Sandlands Road Walton On The Hill Surrey KT20 7XA

    23/02570/TPO Submitted 14 Dec 2023 72m away

    T1, 1x Mature has tree with large of amounts of decay and multiple large cavity?s within the crown. Reduce and reshape the crown by 1-1.5 metres to reduce the weight on heavily decaying limbs. Remove major deadwood. The goal of the work is to minimise the risk of any limb failures and to prolong the trees life.

    Granted Trees 13 docs

In Reigate and Banstead

  • 26/00996/PDE Granted

    89 Mansfield Drive Merstham Surrey RH1 3JW

    Single storey rear extension. Max height 3.35m, height at eaves 3.00m and 4.50m extending beyond the rear wall.

    9 Jun 2026 Prior approval
  • 26/00853/PAP3MA Granted

    Crown House 2 - 8 Gloucester Road Redhill Surrey RH1 1FH

    Change of use from Class E to C3 (16 units).

    18 May 2026 Prior approval
  • 26/00938/PDE Granted

    11 Woodgavil Banstead Surrey SM7 1AA

    Single storey rear extension. Max height 2.72m, height at eaves 2.60m and 8.00m extending beyond the rear wall.

    1 Jun 2026 Prior approval
  • 26/00825/PAP3MA Refused

    Lorimers 46 High Street Banstead Surrey SM7 2LX

    Conversion of first floor of part of a Use Class E property to a 2 bedroom flat (Use Class C3) with ancillary space on the ground floor.

    13 May 2026 Prior approval
  • 26/00872/PDE Granted

    The Wilton 27 Wilton Road Redhill Surrey RH1 6QR

    Single storey rear extension. Max height 3m, height at eaves 3m and extending 6m beyond the rear wall.

    20 May 2026 Prior approval