Planning application
CON/23/00682
70 Cadogan Lane, London, SW1X 9DY
Proposal
Details required by condition 3 (Construction Traffic Management Plan (CTMP)) of planning permission 22/02756 (Variation of Condition 2 (compliance with approved drawings) of planning permission PP/21/02844 to swap places of entrance door and window on ground floor front elevation; revise layout of skylights).***WITHDRAWN***
As published by the council, reference CON/23/00682
Timeline
Dates from the published record
-
31 Jan 2023
Received by Kensington and Chelsea
-
28 Mar 2023
Decision issued: Withdrawn by Applicant
-
3 Aug 2026
Added to PlanIndex
What withdrawal means
The process from here
The applicant withdrew this application before the council decided it, so it carries no planning weight and no fee refund is automatic. Withdrawal often follows officer feedback that a refusal was likely.
The applicant is free to submit a revised application at any time, and many withdrawn schemes return in amended form, so the site is worth watching if the proposal affected you.
About conditions applications
How this application type works
This type of application deals with conditions attached to an existing permission, either by supplying the details a condition requires, called discharging it, or by asking to vary or remove one. It does not reopen the principle of the permission itself. Building often cannot lawfully start, or continue past a set stage, until the named conditions are discharged.
Nearby applications
Within 500 metres
-
LB/25/05621 Refused
Lower Ground, Ground and First Floors, 63 Cadogan Place, London, SW1X 9RS
Reconfiguration and refurbishment of lower ground, ground and first floors; removal of unsympathetic, poor quality extensions to rear and introduction of proportionate extensions
-
PP/25/05620 Refused
Lower Ground, Ground and First Floors, 63 Cadogan Place, London, SW1X 9RS
Reconfiguration and refurbishment of lower ground, ground and first floors; removal of unsympathetic, poor quality extensions to rear and introduction of proportionate extensions
-
CON/26/02568 Granted
68 Cadogan Place, London, SW1X 9RS
Details required by Condition 9 (Submission of details) of Listed Building consent LB/26/00030 (Refurbishment of 68 Cadogan Place, including internal alterations and partial reconstruction of the rear mews house).
-
CON/26/00120 Granted
54 Cadogan Place, London, SW1X 9RT
Details required by condition 3m (Submission of details-New fireplaces) of listed building consent 23/05198 (Internal and external alterations including replacement of existing garage with mews house to rear)
-
CON/26/00047 Granted
54 Cadogan Place, London, SW1X 9RT
Details required by condition 3o (Submission of details-New hard flooring) of listed building consent 23/05198 (Internal and external alterations including replacement of existing garage with mews house to rear)
-
ARB/26/02733 Granted
69 Cadogan Lane, London, SW1X 9DT
Prune 1x Loquat at rear
Other conditions applications
In Kensington and Chelsea
-
CON/26/03015 Granted
30-33 Sloane Street, 49 Pavilion Road, 2-4 Hans Crescent and Garages to rear of Marland House, London, SW1X 9NE
Details required by Condition 16 (Thames Water - works) of planning permission 22/06706 (Partial demolition of 30-33 Sloane Street, retention of fa?ade and erection of a 5-storey building of Class E (commercial, business and service) including installation of shopfronts. Total demolition of no.2 Hans Crescent and erection of replacement building to provide Class E floorspace including a rooftop terrace. Reconfiguration and extension of ground floor of no. 49 Pavillion Road to re-provide Class E floorspace, including service corridor. Provision of substation in basement of no. 4 Hans Crescent. Provision of cycle storage and facilities, waste storage, plant, landscaping, photovoltaic panels, and other ancillary works (Major Application).
-
CON/25/05245 Granted
Ground Floor Flat (north), 36 Holland Park, London, W11 3TA
Details required by Condition 3c-j(inclusive) (Submission of drawings) of listed building consent LB/24/08507 (Replacement of unoriginal windows and internal alterations to include relocation of kitchen, instate a door-cum-window to access rear garden, relocation of boiler and its flue, relocation of gas meter, to alter internal partitioning to reinstate a master suite, alteration to internal partitioning to allow for guest bedroom, new applied timber flooring atop original flooring, replacement of internal fireplace, and proposed joinery above existing skirting and below existing ceiling)
-
CON/26/02799 Withdrawn
Flat 4, 74 Cadogan Square, London, SW1X 0EA
Details required by condition 4 (Submission of details) of listed building consent 26/00634 (Installation of new kitchen, new WC,?new bathroom.?Replacement of?flooring, skirting boards,?lighting?and?redecoration throughout)
-
CON/26/04041 Awaiting decision
8 Crescent Place, London, SW3 2EA
Details required by condition 3 (submission of details) of planning permission PP/25/02821 (Amalgamation of works approved under planning permissions PP/24/05889, PP/24/08563 and PP/24/08565 along with two new underground plant areas and the demolition and replacement of the two garden facing elevations)
-
CON/26/03149 Granted
52 Ladbroke Grove, London, W11 2PB
Details required by condition 5 (sample panel) of planning permission 24/07502 (Variation of Condition 2 (compliance with approved drawings) of planning permission PP/24/05464 to increase the width of the side extension at the lower ground floor level and installation of pipe (amended description))