Planning application
Greenfield Academy Greenfield Way Newton Aycliffe DL5 7LF
Still open. Anyone can comment while the consultation period runs, and comments go to the council rather than to us.
Proposal
Greenfield Academy signage to be mounted on the end elevation of the new teaching block and extended Sports Centre Building
As published by the council, reference DM/26/01838/AD
Application record
- Reference
- DM/26/01838/AD
- Status
- Pending Consideration
- Received
- 16 Jul 2026
- Validated
- 17 Jul 2026
- Postcode
- DL5 7LF
Timeline
Dates from the published record
-
16 Jul 2026
Received by County Durham
-
17 Jul 2026
Validated
Checked as complete and ready for consideration.
-
6 Aug 2026
Added to PlanIndex
-
Decision
Awaiting decision
Decision expected by 11 September 2026, 8 weeks from validation under the statutory target for most applications. Extensions of time are common and are agreed case by case.
County Durham took a median of 56 days over the applications it decided in the last year.
What happens while it is decided
The process from here
This application is with County Durham for determination. The council publicises it, consults neighbours and technical bodies where required, and weighs the responses against local and national planning policy.
The statutory target is eight weeks for most applications and thirteen for major development, though extensions of time are common. Comments carry most weight while the case is undecided, so check the council portal for the deadline if you want to respond.
About this record
Reading the register
This page mirrors an entry on the statutory planning register that County Durham is required to keep. The published feed for this record does not state which type of application it is, which is common for older entries and for some council systems; the register entry on the council portal will say, alongside the case officer and any consultation dates.
Every planning application follows the same broad path: submission, validation, publicity, then a decision by officers or committee. Our guide to planning application types explains the common types and what each can approve.
Nearby applications
Within 500 metres
-
Greenfield Academy Greenfield Way Newton Aycliffe DL5 7LF
97% historically approved · decision due ~12 Oct
There were previoulsy no alterations to the existing front east elevation at the main entrance to the school, this amendments seeks approval for the enhancement of this elvation with a Cedral click horizontal cladding to the main existing elevation
Awaiting decision Amendments -
Greenfield Academy Greenfield Way Newton Aycliffe DL5 7LF
94% historically approved · decision due ~21 Sep
Discharge of conditions 12 (hard and soft landscaping proposals), 20 (electric vehicle parking) and 21 (cycle parking) of planning permission DM/24/00834/FPA.
Awaiting decision -
Greenfield Academy Greenfield Way Newton Aycliffe DL5 7LF
Condition 10: Greenfield Community College - New System - EW.pdf - Solar For Schools design information pack. Greenfield Academy - SolarForSchools - layout.pdf - Updated drawing of PV layout coordinated with other roof penetrations. DS_20231219_SG36_40_50CX-P2_Datasheet_V4_EN.pdf - Datasheet for PV Panel Inverter Condition 15: External Plant: LA002-GEM-01-RF-D-Z-5001.pdf - Teaching Block Roof Plan showing Plant LA002-GEM-03-01-D-M-5001 - Sport Block Plantroom.pdf - Sport Block Roof Plan showing Plant LA002-GEM-XX-00-D-Z-5001 - Energy Centre.pdf - Energy Centre Layout showing Plant M6as-RAV-GM1101ATP-E-outdoor-unit-Data-sheet-single-page-1.pdf - A/C for Teaching Block x3 units CAHV-R450YA-HPB_Product_Information_Sheet(2).pdf - ASHP for Sports Block x2 units M6as-RAV-GM301ATP-E-outdoor-unit-Data-sheet-single-page-1.pdf - A/C for Sports Block x1 unit EAHV-M1500YCL-N.pdf - ASHP for Energy Centre x2 units Internal Plant: LA002-GEM-01-00-D-M-5701 Ground Floor Ventilation.pdf - GF Teaching Block LA002-GEM-01-01-D-M-5701 First Floor Ventilation.pdf - FF Teaching Block LA002-GEM-01-02-D-M-5701 Second Floor Ventilation.pdf - SF Teaching Block LA002-GEM-03-00-D-M-5701.pdf - Sport Block Block Ventilation Layout Nuaire MVHR Extract Fans.pdf - Heat Recovery/Extract units within Teaching Block/Sports Block (locations stated on each page) HVR.pdf - Hybrid Ventilation Units in Teaching Rooms (connected to window vents)
Granted Conditions Windows or glazing 3 docs -
Greenfield Academy Greenfield Way Newton Aycliffe DL5 7LF
Discharge of Condition 6 (Demolition Management Plan) pursuant to planning permission DM/24/00834/FPA
Granted Conditions Demolition 7 docs -
Greenfield Academy Greenfield Way Newton Aycliffe DL5 7LF
PARTIAL Discharge of Condition 10 (Details of colours and finishes) pursuant to Planning Permission No. DM/24/00834/FPA
Granted Conditions 3 docs -
Greenfield Academy Greenfield Way Newton Aycliffe DL5 7LF
Discharge of Condition 18 (Biodiversity Management Plan) pursuant to planning permission DM/24/00834/FPA
Granted Conditions 5 docs