Planning application
20/2402
Orange Site Roof of 97-135, Watling Gardens, London, NW2 3UB
Proposal
Upgrade of existing rooftop telecommunications base station
As published by the council, reference 20/2402
Timeline
Dates from the published record
-
7 Aug 2020
Received by Brent
-
2 Oct 2020
Decision issued: Permission Granted
-
25 Jul 2026
Added to PlanIndex
What a grant of permission means
The process from here
Permission has been granted, usually subject to conditions listed on the decision notice, some of which must be discharged before work starts. The decision notice on the council portal sets out exactly what was approved.
Work must normally begin within three years of the decision or the permission lapses. Neighbours cannot appeal a grant; challenging one means judicial review of how the decision was made, within tight time limits.
About full applications applications
How this application type works
A full application seeks permission for a complete, detailed proposal in one go: siting, design, access and landscaping are all fixed at this stage. It is the standard route for new buildings, conversions and changes of use. The statutory target is eight weeks for smaller schemes and thirteen weeks for major development, though complex cases often take longer by agreement.
Nearby applications
Within 500 metres
-
26/0033/TELN Decided
Telecommunications Site Roof of 97-135, Watling Gardens, London, NW2 3UB
Telecommunication notification for Existing H3G 11751 Local Fibre BOB and 11748v3 Local DC BOB mounted to gantry pole. Existing H3G ICD 11748v3 DC BOB to be converted to 11748v4 in situ Existing H3G 1No. Ericsson RBS 6130 cabinet installed on steel grillage c/w DCDU & 1No. GNSS receivers to be reused. Proposed H3G 1No. 6672 BBU to be installed within. Existing 1No. 6648 BBU and 1No. 6647 BBU to be removed. Proposed H3G 1No. Interleaved AIR3218 antenna to be installed on existing Valmont tripod steelwork support pole Existing H3G 1No. Hybrid AIR3278 antenna to be removed. Existing H3G 1No. ERS2460 (800) and 1No. ERS4020 (14) on existing rail mounted to support pole to be re-used. Existing 1No.ERS4480 (18/21) to be removed and replaced with proposed 1No. ERS4485 (18/21/26) to be fixed with ERS bracket (Part No. SEF 901 377/2) on existing ERS rail clamped to existing tri-pod support pole. 700 and 900 to be activated on existing ERS2460. Existing H3G 1No. remote DC BOB (11752) to be swapped with 1No. Remote DC BOB (12070) to be installed on existing roofpod support pole. Existing H3G 1No. Remote fibre BOB (11753) to be reused. Proposed H3G stepover to be installed over existing cable tray on free-standing blocks for safe access. Refer to drawing 601 for details. Proposed H3G 1No. Interleaved AIR3218 antenna to be installed on existing Valmont tripod steelwork support pole Existing H3G 1No. Hybrid AIR3278 antenna to be removed. Existing H3G 1No. ERS2460 (800) and 1No. ERS4020 (14) on existing rail mounted to support pole to be re-used. Existing 1No.ERS4480 (18/21) to be removed and replaced with proposed 1No. ERS4485 (18/21/26) to be fixed with ERS bracket (Part No. SEF 901 377/2) on existing ERS rail clamped to existing tri-pod support pole. 700 and 900 to be activated on existing ERS2460 Existing H3G 1No. ERS2460 (800) and 1No. ERS4020 (14) on existing rail mounted to support pole to be re-used. Existing 1No. ERS4480 (18/21) to be removed and replaced with proposed 1No. ERS4485 (18/21/26) to be fixed with ERS bracket (Part No. SEF 901 377/2) on existing ERS rail clamped to existing tri-pod support pole. 700 and 900 to be activated on existing ERS2460. Existing H3G 1No. remote DC BOB (11752) to be swapped with 1No. Remote DC BOB (12070) to be installed on existing roofpod support pole. Existing H3G 1No. Remote fibre BOB (11753) to be reused. Proposed H3G 1No. Interleaved AIR3218 antenna to be installed on existing Valmont tripod steelwork support pole Existing H3G 1No. Hybrid AIR3278 antenna to be removed. Existing H3G 1No. ERS2460 (800) and 1No. ERS4020 (14) on existing rail mounted to support pole to be re-used. Existing 1No. ERS4480 (18/21) to be removed and replaced with proposed 1No. ERS4485 (18/21/26) to be fixed with ERS bracket (Part No. SEF 901 377/2) on existing ERS rail clamped to existing tri-pod support pole. 700 and 900 to be activated on existing ERS2460. Existing H3G 1No. remote DC BOB (11752) to be swapped with 1No. Remote DC BOB (12070) to be installed on existing roofpod support pole. Existing H3G 1No. Remote fibre BOB (11753) to be reused and associated ancillary works ath location Watling Gardens, 96-135 Watling Gardens, Shoot-Up Hill, Brent, London, NW2 3UD NGR E:524455, N: 184790 (Notification under Electronic Communications Code (Conditions and Restrictions) Regulations 2003 (As Amended) to Utilise Permitted Development Rights
-
26/1822 Awaiting decision
Flat 1, 1 Exeter Road, London, NW2 4SJ
T2 Hazel- Remove The tree works are proposed to stop the influence of the tree(s) on the soil below building foundation level and provide long term stability at 1A Exeter Road, London, NW2 4SJ
-
26/1820 Awaiting decision
Flat A, Flat 1-10, Dene, 1A Exeter Road, London, NW2 4SJ
S1 Lilac- Remove T3 Apple- Remove T4 Apple- Remove The tree works are proposed to stop the influence of the tree(s) on the soil below building foundation level and provide long term stability.
-
26/1823 Awaiting decision
3 Exeter Road, London, NW2 4SJ
T6 Honey Locust - Fell
-
22/3688 Granted
9C Exeter Road, London, NW2 4SJ
Proposed rear dormer window roof extension and installation of 1 x side facing window to second floor flat (Amended Description)
-
20/2732 Granted
1-19 Wiltern Court, Shoot Up Hill, London, NW2 3TY
Prior approval for erection of two additional storeys to accommodate 6 residential units to detached residential block
Other full applications applications
In Brent
-
26/1435 Granted
202A Preston Road, Wembley, HA9 8PA
Proposed rear dormer extension, installation of rooflights and alteration to entryway to the first floor flat.
-
26/1315 Refused
1 & 2 Zyad Close, London, NW10 9BB
Joint application for proposed erection of 1x new storey to roof of 2x existing two-storey dwellinghouses
-
26/0820 Granted
105 Dollis Hill Lane, London, NW2 6HS
Proposed rear dormer extension, hip to gable roof extension, new pitched roof to first floor and installation of rooflights to the dwellinghouse.
-
26/0529 Refused
24 Staverton Road, London, NW2 5HL
Proposed single-storey rear extension, raised patio decking and outbuilding in the rear garden of the ground floor flat
-
26/1367 Granted
69, 71, 73 & 75 Goldsmith Lane, London, NW9 9AR
Installation of a new rainwater hopper and down pipe to the front elevation of building