Planning agent
Trident Engineering Consultants
An engineering consultancy registered in Paisley. 8 planning applications on PlanIndex across 5 councils . On the register from 2018 to 2026.
- 8 Applications on record
- 3 In the last 12 months
- 5 Councils
- Too few Decisions to give a rate
Where they work
-
-
-
York1
-
-
What they file
-
Conditions50%
-
Advertising13%
-
Amendments13%
-
Full applications13%
-
Prior approval13%
Company record
From Companies House. Company information only; we never show personal contact details.
- Registered name
- TRIDENT ENGINEERING CONSULTANTS LIMITED
- Company number
- SC145230
- Status
- Active
- Incorporated
- 30 June 1993
- Registered in
- Paisley
Track record
The 8 most recent applications naming this firm
-
DC/26/1300/DRC Awaiting decision
Haven Filling Station Dock Road The Docks Felixstowe Suffolk IP11 3SH
Discharge of Condition Nos. 4 and 10 of DC/23/2349/FUL - Two double skinned fuel tanks will be installed on the existing site for the offloading and loading of fuels. These tanks will be installed on new reinforced concrete slabs. An electrical GRP pre-fabricated unit will be installed for the electrical connections. A catchment area around the two tanks will be surrounded by drainage channels to capture any spills and runoff from the loading of trucks. These channels will lead to sumps which will be connected to a full class 1 interceptor. Existing underground tanks to be foam filled. - OHES Level 4 Assessment and OHES Supplementary Environmental Assessment
-
DC/26/1299/VOC Awaiting decision
Haven Filling Station Dock Road The Docks Felixstowe Suffolk IP11 3SH
Variation of Condition Nos. 2, 4 & 6 of DC/23/2349/FUL - Two double skinned fuel tanks will be installed on the existing site for the offloading and loading of fuels. These tanks will be installed on new reinforced concrete slabs. An electrical GRP pre-fabricated unit will be installed for the electrical connections. A catchment area around the two tanks will be surrounded by drainage channels to capture any spills and runoff from the loading of trucks. These channels will lead to sumps which will be connected to a full class 1 interceptor. Existing underground tanks to be foam filled. - Condition 02 - change to allow for minor site layout amendments: -Installation of an additional six-hose dispenser and associated small island linked to Tank 1, including leak-detected underground pipework, to improve traffic flow and reduce standing vehicles. - Replacement of the full concrete yard within the Certas boundary with Hardicrete. - Minor layout adjustments, including relocation of lighting columns and slight positional refinements to suit the revised arrangement. - Increase width of site entrance. Condition 04 and Condition 06 - Change wording: As per discussion with planning officer and environment agency consultation (Letter ref. DC/23/4835/DRC) due to nature of required information for referenced conditions, it was advised that the correct procedure would be the submission of a variation of condition application (to allow of submittal of required information during construction / prior site occupation) where any subsequent conditions can also be amended to reflect the required action/works being undertaken in order to effectively discharge this condition.
-
DC/26/0888/ADI Awaiting decision
Haven Filling Station Dock Road The Docks Felixstowe Suffolk IP11 3SE
Illuminated Advertisement Consent - The installation of totem pole sign 6.5m x 1.8m with associated foundation.
-
DC/23/4835/DRC Granted
Haven Filling Station Dock Road The Docks Felixstowe Suffolk IP11 3SE
Discharge of Conditions 3, 4 & 10 of DC/23/2349/FUL - Two double skinned fuel tanks will be installed on the existing site for the offloading and loading of fuels. These tanks will be installed on new reinforced concrete slabs. An electrical GRP pre-fabricated unit will be installed for the electrical connections. A catchment area around the two tanks will be surrounded by drainage channels to capture any spills and runoff from the loading of trucks. These channels will lead to sumps which will be connected to a full class 1 interceptor. Existing underground tanks to be foam filled. - Oil Spill Incident Response Plan, Site Redevelopment Phasing Letter & Pilling Risk Assessment Submitted.
-
20/00393/DISCON Decided
Doe Hill Depot Doe Hill Lane Tibshelf Alfreton DE55 6JS
Discharge of Condition 6 (Noise Management Plan) of Planning Permission 19/00142/FUL
-
AOD/19/00320 Granted
Certas Energy UK Ltd Shell Direct 3 Derwent Valley Industrial Estate Dunnington York YO19 5PD
Condition 3 of permitted application 19/01015/FUL
-
19/00213/FULL Withdrawn
Littlefair Road HGV Bunkering Facility Kingston Upon Hull HU9 5LP
Installation of a double-skinned rectangular steel HGV fuel storage tank with dispensers
-
DEM/2018/0002 Decided
Unit 7 Javel Industrial Estate Three Cocks Brecon LD3 0SL
DEM: Demolition notification: removal of modular office building. Demolition of 7 horizontal steel fuel storage tanks and brick supports. Removal of all above ground pipework and valves, etc. Demolition of steel canopy structure and associated walkways. Removal of all steel walkways. Breaking out and removal of all associated concrete plinths.
The full track record
Trade members see everything this firm has filed, filter it by council and outcome, and get an email the day it files again.
See the full track recordFrom council registers and Companies House. Counts describe the records we hold, not a firm's complete history. Request a correction or removal.